3 a trouble signal was an indication that some part of the fire alarm system was broken or off normal.
Fire alarm panel trouble signal.
Trouble signal a trouble signal is typically designated by a yellow light and means that there is an operational issue.
Fire alarm trouble signal.
Some wiring from the control panel to the devices in the house is supervised for integrity.
At this point the system will send a signal to the central station and clear your communication failure.
A supervisory signal was used to indicate that some other protection system monitored by the fire alarm system was off normal.
With any of these signals most fire panels will also have a digital display that will tell you what type of signal is active.
Potter electric signal company is a st.
Another signal is the trouble signal or trouble condition.
Watch this video as orr vp of engineering lee kaiser walks us through the common causes for many trouble signals and the.
A trouble signal will also have a yellow light or led lit on the fire panel and there will be a slower beeping tone sounding from the panel.
Trouble signals occur due to ground faults circuit problems battery faults or other failures within the system.
Contacting your fire equipment service provider a certified fire alarm technician or a qualified electrician would be the prudent thing to do.
The reset button only resets the panel after a fire alarm.
Here are some of the common reasons for a trouble signal.
Some fire alarm panels may indicate the type of fire alarm trouble and its location.
There are three basic categories for fire alarm panel signals.
It will not reset any trouble.
The thing is having worked with a lot of fire alarm panels you know that a panel showing a trouble is a panel indicating that something is wrong with the fire alarm system.
An alarm meant a warning of fire danger.
Something is not normal and it needs to be fixed.
Many of the messages you see displayed here indicate a fault with your system that may require immediate attention and service.
For some more advanced systems the panel may indicate the kind of problem and where it is located.
Here s an explanation of what each fire alarm panel signal means.
When fire alarm panels are in trouble condition it can be difficult to find the root cause of the problem.
It could be a loss of power.
Common fire alarm trouble indications.
If this does not work you ll need a service call so that a trained technician can assess and fix the problem.
In the past fire alarm terminology was fairly simple.
Louis missouri based manufacturer of sprinkler monitoring devices fire alarm systems and corrosion solution products.
Trouble supervisory and alarm.