The conmpany s soffit and eaves vents prohibit flame intrusion through a structure s ventilation system.
Fire rated attic vents.
As seen on this old house vulcan vents are designed to be fire and ember safe.
When a wildfire nears and the vent reaches the critical temperature the intumescent coating on the matrix structure expands creating an insulating barrier from fire and embers.
When used in conjunction with lower soffit or eave vents rapid cooling and venting of the attic can take place.
Vulcan vents are the perfect fire stopping vent for your home.
Vents are vulnerable to wildfires when embers and flames enter into the enclosed attic or crawl spaces and ignite combustible materials in those areas.
It shows fire penetrating a frieze block vent with flames entering into what would be the attic.
The core of our fire and ember safe vents are manufactured out of hi grade aluminum honeycomb and coated with an intumescent fire proof coating.
Today o hagin has local and national testing approvals.
This is a photograph from a test conducted in a fire research laboratory.
Gables like dormers are vertically oriented vents best placed as high as possible.
The vulcan vents are the only fire resistant vents that meet both the wildland urban interface wui and the one 1 hour fire test standards for the exterior of buildings all while providing the proper amount of ventilation to attic and crawl spaces in building structures.
O hagin universal direct deck attic vents this attic vent provides maximum net free ventilation area nfva and is designed for mop in or dry in applications using tile shingles slate or shake.
Under eave soffit vents important airflow notes.
Flame ember resistant vents naturally provide less airflow than regular unprotected vents and brandguard vent airflow ratings nfva are approximately 30 that of the same size standard 1 4 screened vent and are listed within each products description.
Common 1 4 screens are ineffective and should be replaced or retrofitted.
Is recognized for its industry leading efforts in research development and testing.
Quick reference as well as more pics and info for gable vents.
The intumescent coating is designed to quickly swell up and close off when exposed to high heat.
Alternatively cover all existing vent openings with 1 8 inch or 1 16 inch wire mesh.
Vulcan vents are listed by the california state fire marshal under category 8165 of the building material listing program.
These patented attic vents are accepted for use by many local fire officials for installation in wildland urban interface wui zones.
From its founding roots as a roofing company over 40 years ago o hagin has grown into a nationally recognized designer and producer of top quality state of the art attic ventilation solutions.